Product overview
TPS reactive adhesive polymer membrane-based waterproofing membrane is a special anti-adhesive waterproof material for basement floor made of imported high-strength resin as tire base, asphalt-based reactive strong adhesive binder, UV-resistant chemical sand on the upper surface and silicone oil isolation film on the lower surface. The waterproofing membrane and the bottom plate concrete form full adhesion to protect the structural safety. Its structure from top to bottom are: UV-resistant white sand, reactive strong adhesive, high-strength resin film base, reactive strong adhesive, silicone oil isolation film.
Specifications: 1.5mm thick; 1000mm wide; 15/20m long
Product Features
♦Dedicated for the bottom plate of underground works;
♦Anti-stick type construction, UV-resistant chemical white sand in the protection of the coiled material at the same time, but also with the effective components of the concrete chemical cross-linking, to ensure that the waterproof coiled material and the building structure is firmly bonded without water channeling, to ensure the safety of the building structure.
♦The coil has high strength and large extension, which can resist structural stress deformation;
♦Excellent dimensional stability, no deformation of the coil after construction at any ambient temperature;
♦Impermeability is extremely strong, resistance to hydrostatic pressure up to 60m;
♦Cold construction, energy saving and environmental protection;
♦Can avoid playing protective layer, cost savings 35 yuan/square meters.
-- Performance indicators--
Serial Number
|
Project
|
Indicators
|
1
|
Tensile force/(N/50mm) ≥
|
600
|
2
|
Elongation at break of film/% ≥
|
100
|
3
|
Tearing force/N≥
|
30
|
4
|
Heat resistance/℃ (70 ℃,2h)
|
No flowing, dripping and slippage ≤ 2mm
|
5
|
Low temperature flexibility/℃(-20 ℃)
|
No crack
|
6
|
Watertight/MPa(120min watertight)
|
0.6
|
9
|
Peel strength between coil and coil (overlap edge)/(N/mm)
|
1.0
|
10
|
Peel strength with post-cast concrete/(N/mm) ≥
|
1.5
|
11
|
Peel strength after immersion with post-cast concrete/(N/mm) ≥
|
1.0
|
12
|
static load
|
20Kg without leakage
|
13
|
Anti-channeling water
|
0.6MPa no water channeling
|
14
|
Dimensional change rate/% ≤
|
1.0
|
15
|
Thermal stability/(70 ℃,24h)
|
No drum, flowing
|
Scope of application and scheme optimization
l Scope of application:Industrial and civil construction underground engineering floor, civil air defense engineering, urban pipe gallery floor, tunnel and other waterproof works.
l Scheme Optimization:Grade II waterproof single-layer waterproof coiled material; Grade I waterproof permeable crystalline waterproof coating composite waterproof coiled material.
Construction process
- Pre-laid anti-sticking
Basic requirements:
► The base maintenance meets the design and specification requirements, and the waterproof construction is qualified according to the specification before acceptance;
All kinds of embedded pipe fittings shall be embedded in advance and sealed according to the design and specification requirements.
► The base course shall be solid, smooth, clean and free of protrusions;
The yin and yang corners of the grass-roots level should be wiped into a circular arc, with a minimum radius of 50mm for the yin and yang corners and a minimum radius of 20mm for the yang corners;
► There is no open water at the base during construction. If there is open water, the construction can be carried out after sweeping the open water.